A general vector inverter is equipment that adjusts motor rotating speed by changing the frequency of input power supply for motors, which is widely applied in modern industrial automation.
Working Principle
The core technology of general vector inverters is vector control. It precisely controls motor torque and magnetic field, and dynamically adjusts motor speed following load fluctuation to achieve higher-efficiency and smoother operation.
Performance Advantages
Precise Control
Adopting vector control technology, the motor maintains highefficiency operation under low speed and heavy load conditions, realizing high-precision speed and torque control.
Energy Saving & High Efficiency
Compared with conventional fixedfrequency drive systems, the inverter runs stably in a wide frequency range, improving motor operating efficiency and cutting power consumption for energy conservation.
Strong Adaptability
It supports multiple control modes including sensorless vector control and V/F control to match diverse load requirements. Meanwhile, it accepts multiple frequency reference inputs such as analog signals, pulse signals and communication commands, adapting to complicated and variable industrial site conditions.
Comprehensive Protection Functions
It is equipped with complete fault selfdiagnosis and protection mechanisms covering overcurrent, overvoltage, undervoltage, overheating, phase loss, short circuit and other safety detections to guarantee long-term stable equipment operation.
Inverter Technical Specifications
| Category | Item | Technical Parameters |
|---|---|---|
| Basic Functions | Frequency Command | Digital setting: 0.01Hz; Analog setting: Max. frequency × 0.025 |
| Control Mode | Open-loop Vector Control (SVC); Closed-loop Vector Control (FVC); V/F Control | |
| Starting Torque | 0.25Hz / 150% (SVC); 0Hz / 180% (FVC) | |
| Speed Regulation Range | 1 : 200 (SVC) 1 : 1000 (FVC) | |
| Speed Stability Accuracy | ±0.5% (SVC) ±0.02% (FVC) | |
| Torque Control Accuracy | FVC: ±2%; SVC: ±5% above 5Hz | |
| Torque Boost | Automatic torque boost; Manual torque boost: 0.1%~30.0% | |
| V/F Curve | Five modes: Linear; Multi-point; Square V/F; Full V/F separation; Partial V/F separation | |
| Acceleration/Deceleration Curve | Linear or S-curve acceleration/deceleration; Four sets of accel/decel time, range: 0.0~6500.0s | |
| DC Braking | DC braking start frequency: 0.00Hz~Max. frequency; Braking time: 0.0s~36.0s; Braking current: 0.0%~100.0% | |
| Jog Control | Jog frequency range: 0.00Hz~50.00Hz; Jog acceleration/deceleration time: 0.0s~6500.0s | |
| Simple PLC & Multi-speed Operation | Up to 16-speed operation via built-in PLC or control terminals | |
| Built-in PID | Facilitates closed-loop process control systems | |
| Personalized Functions | Automatic Voltage Regulation (AVR) | Automatically maintains constant output voltage when grid voltage fluctuates |
| Overvoltage/Overcurrent Stall Prevention | Automatically limits current and voltage during operation to prevent frequent overcurrent/overvoltage trips | |
| Fast Current Limiting Function | Minimizes overcurrent faults and protects normal inverter operation | |
| Torque Limit & Control | Automatically limits torque during operation to prevent frequent overcurrent trips; Torque control available in vector mode | |
| Ride-through on Momentary Power Loss | Compensates voltage drop through load regenerative energy during momentary power loss, sustaining short-time inverter operation | |
| Fast Current Limiting | Prevents frequent overcurrent faults of the inverter | |
| Virtual I/O | Five sets of virtual DI/DO for simple logic control | |
| Timer Control | Timer control function: Setting range 0.0min~6500.0min | |
| Multi-motor Switching | Two sets of motor parameters for switching between two motors | |
| Multi-fieldbus Support | Supports four fieldbuses: Modbus, Profibus-DP, CANlink, CANopen | |
| Motor Overheat Protection | With optional I/O expansion card 1, analog input A13 accepts motor temperature sensor input (PT100, PT1000) | |
| Multi-encoder Support | Supports differential, open-collector, UVW, resolver, etc. | |
| User Programmable | With optional user programmable card for secondary development; programming compatible with Inovance PLC | |
| Powerful Background Software | Supports inverter parameter operation and virtual oscilloscope function; internal status monitoring via virtual oscilloscope | |
| Operation Command | Given via operation panel, control terminals, or serial communication port. Switchable via multiple methods | |
| Frequency Command | 10 frequency command sources: Digital setting, analog voltage, analog current, pulse, serial port. Switchable via multiple methods | |
| Auxiliary Frequency Command | 10 auxiliary frequency commands. Flexible for fine-tuning and frequency synthesis | |
| Operation | Input Terminals | Standard: 5 DI terminals (1 supporting high-speed pulse input up to 100kHz); 2 AI terminals (1 for 0~10V only, 1 for 0~10V or 0~20mA) Expansion: 5 DI terminals, 1 AI terminal supporting -10V~10V and PT100/PT1000 |
| Output Terminals | Standard: 1 high-speed pulse output (optional open-collector), 0~100kHz square wave; 1 DO, 1 relay output, 1 AO (0~20mA or 0~10V) Expansion: 1 DO, 1 relay output, 1 AO (0~20mA or 0~10V) | |
| Display & Keyboard | LED Display | Displays parameters |
| LCD Display | Optional; Chinese/English operation prompts | |
| Parameter Copy | Quick parameter copy via optional LCD operation panel | |
| Key Lock & Function Selection | Partial or full key lock; definable key function scope to prevent misoperation | |
| Protection Functions | Phase Loss Protection | Input phase loss protection, output phase loss protection |
| Instantaneous Overcurrent Protection | Shuts down at above 250% of rated output current | |
| Overvoltage Protection | Shuts down when DC bus voltage exceeds 820V | |
| Undervoltage Protection | Shuts down when DC bus voltage drops below 350V | |
| Overheat Protection | Triggered when inverter bridge overheats | |
| Overload Protection | Shuts down after 60s at 150% rated current | |
| Overcurrent Protection | Shuts down when current exceeds 2.5× rated inverter current | |
| Braking Protection | Braking unit overload protection, braking resistor short-circuit protection | |
| Short Circuit Protection | Output phase-to-phase short circuit protection, output ground short circuit protection | |
| Environment | Installation Site | Indoor, free from direct sunlight, dust, corrosive gas, flammable gas, oil mist, steam, dripping water, or salt |
| Altitude | No derating below 1000m; 1% derating per 100m above 1000m; Max. altitude 3000m (contact factory above 3000m) Note: Max. altitude for 0.4~3kW drives is 2000m (contact factory above 2000m) | |
| Ambient Temperature | -10°C~+50°C; derating required at 40~50°C, 1.5% derating per 1°C increase | |
| Humidity | <95% RH, non-condensing | |
| Vibration | <5.9m/s² (0.6g) | |
| Storage Temperature | -20°C~+60°C |
Product Functions
Basic Functions: Including open-loop speed control, closed-loop process control, open-loop torque control, motor auto-tuning, motor pre-excitation, automatic slip compensation, automatic load compensation, automatic voltage regulation and other functions.
Application Functions: Equipped with swing frequency control, jog control, external multispeed operation, simple PLC, mechanical brake control, UP/DOWN function and so on.
Application Scenarios: General vector inverters are applied in numerous industries. When used for fans, water pumps, air compressors and other equipment, they optimize operating status to cut power loss and enhance system stability and safety. For CNC machine tools, textile machinery, food processing and other industries, they cope well with complex working conditions such as heavy-load startup and impact load to ensure stable operation of equipment.


Abbreviated as Taichuan Intelligent, the enterprise was founded in 2008. It is a technology focused enterprise integrating research and development production sales and technical service of industrial inverters. More than fifty percent of the company staff are professional technicians proficient in frequency conversion technology, supporting strong product development and technical service capacity.
The company deploys high speed automatic assembly lines for inverter manufacturing within the industry. All series products independently developed by the enterprise feature powerful functions flexible control and reliable performance. The products can meet demands for mechanical supporting system integration and industrial application, and have been widely applied in machine tool textile lifting oilfield plastic chemical industry industrial automation and other fields.
Taichuan Intelligent operates one research and development center two production bases ten domestic offices and numerous authorized distributors. Its products are exported to the Middle East Africa Southeast Asia and other overseas regions. The enterprise owns professional technical service teams for pre sales in sales and after sales phases to deliver full cycle professional service for all customers.